{"id":5811,"date":"2017-06-27T18:13:59","date_gmt":"2017-06-27T16:13:59","guid":{"rendered":"http:\/\/x01_415.lux01.de\/_ntg\/profilgitter\/"},"modified":"2017-12-14T09:07:22","modified_gmt":"2017-12-14T08:07:22","slug":"profilgitter","status":"publish","type":"page","link":"https:\/\/www.ntg.de\/en\/produkte\/teilchen-beschleuniger\/strahldiagnose\/strahlprofil-monitore\/profilgitter\/","title":{"rendered":"Profile Grids"},"content":{"rendered":"<p>[et_pb_section bb_built=&#8221;1&#8243; custom_padding=&#8221;||0px|&#8221; fullwidth=&#8221;on&#8221; _builder_version=&#8221;3.0.51&#8243;][et_pb_fullwidth_image admin_label=&#8221;Kopfbild blau&#8221; src=&#8221;https:\/\/www.ntg.de\/wp-content\/uploads\/2017\/06\/NTG-IH-Beschleuniger7.jpg&#8221; alt=&#8221;NTG Neue Technologien GmbH &amp; Co. KG&#8221; animation=&#8221;fade_in&#8221; _builder_version=&#8221;3.0.51&#8243; animation_direction=&#8221;center&#8221; animation_style=&#8221;fade&#8221; animation_duration=&#8221;500ms&#8221; animation_intensity_slide=&#8221;10%&#8221;]<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_fullwidth_image][\/et_pb_section][et_pb_section bb_built=&#8221;1&#8243; custom_padding=&#8221;0px|||&#8221; specialty=&#8221;on&#8221; background_position_1=&#8221;top_left&#8221; background_position_2=&#8221;top_left&#8221; background_repeat_1=&#8221;no-repeat&#8221; background_repeat_2=&#8221;no-repeat&#8221; _builder_version=&#8221;3.0.51&#8243;][et_pb_column type=&#8221;3_4&#8243; specialty_columns=&#8221;3&#8243;][et_pb_row_inner admin_label=&#8221;Zeile&#8221; custom_padding=&#8221;||0px|&#8221; background_position_1=&#8221;top_left&#8221; background_repeat_1=&#8221;no-repeat&#8221; _builder_version=&#8221;3.0.51&#8243; background_size=&#8221;initial&#8221; background_position=&#8221;top_left&#8221; background_repeat=&#8221;repeat&#8221;][et_pb_column_inner type=&#8221;4_4&#8243; saved_specialty_column_type=&#8221;3_4&#8243;][et_pb_sidebar admin_label=&#8221;breadcrumb&#8221; area=&#8221;et_pb_widget_area_3&#8243; remove_border=&#8221;on&#8221; _builder_version=&#8221;3.0.51&#8243; header_font_size=&#8221;11&#8243; body_font_size=&#8221;11&#8243; global_module=&#8221;3505&#8243; saved_tabs=&#8221;all&#8221; show_border=&#8221;on&#8221;]<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_sidebar][et_pb_text _builder_version=&#8221;3.0.91&#8243; custom_padding=&#8221;||0px|&#8221; background_layout=&#8221;light&#8221;]<\/p>\n<h1>Profile Grids<\/h1>\n<p>Profile Grids are for measuring the 2d transversal intensity distribution of the beam. With our design we consider the power dissipation on the wires taking the penetration depth and the power density of the incident beam into account. We do detailed thermal simulations to stay within the feasible load limits. And we take care for the thermal expansion of the wires by means of individual sprig tensioning. For high intensity cw beams it might be interesting to switch to one of our moving wire systems like our cross wire scanners.<\/p>\n<p>We are flexible on wire material, pitch and diameter and sizes &#8211; customized is our standard.<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_text][et_pb_image _builder_version=&#8221;3.0.91&#8243; src=&#8221;https:\/\/www.ntg.de\/wp-content\/uploads\/2017\/12\/temperature-on-wire.jpg&#8221; show_in_lightbox=&#8221;on&#8221; url_new_window=&#8221;off&#8221; use_overlay=&#8221;off&#8221; always_center_on_mobile=&#8221;on&#8221; force_fullwidth=&#8221;off&#8221; show_bottom_space=&#8221;on&#8221; max_width=&#8221;66%&#8221; align=&#8221;center&#8221; \/][et_pb_text _builder_version=&#8221;3.0.91&#8243; background_layout=&#8221;light&#8221;]<\/p>\n<p style=\"text-align: center;\">temperature on wire with pulsed beam<\/p>\n<p>[\/et_pb_text][\/et_pb_column_inner][\/et_pb_row_inner][\/et_pb_column][et_pb_column type=&#8221;1_4&#8243;][et_pb_sidebar admin_label=&#8221;Seitenleiste submenue 2017-06-023&#8243; orientation=&#8221;right&#8221; area=&#8221;et_pb_widget_area_1&#8243; module_class=&#8221;firma&#8221; _builder_version=&#8221;3.0.51&#8243; header_font=&#8221;|on|||&#8221; header_font_size=&#8221;19&#8243; global_module=&#8221;3449&#8243; saved_tabs=&#8221;all&#8221;]<\/p>\n<p>&nbsp;<\/p>\n<p>[\/et_pb_sidebar][\/et_pb_column][\/et_pb_section]<\/p>\n<div class=\"shariff shariff-align-center shariff-widget-align-center\" style=\"display:none\"><ul class=\"shariff-buttons theme-white orientation-horizontal buttonsize-medium\"><li class=\"shariff-button facebook shariff-nocustomcolor\" style=\"background-color:#4273c8\"><a href=\"https:\/\/www.facebook.com\/sharer\/sharer.php?u=https%3A%2F%2Fwww.ntg.de%2Fen%2Fprodukte%2Fteilchen-beschleuniger%2Fstrahldiagnose%2Fstrahlprofil-monitore%2Fprofilgitter%2F\" title=\"Share on Facebook\" aria-label=\"Share on Facebook\" role=\"button\" rel=\"noreferrernoopener nofollow\" class=\"shariff-link\" style=\"; background-color:#3b5998; color:#3b5998\" target=\"_blank\"><span class=\"shariff-icon\" style=\"fill:#3b5998\"><svg width=\"32px\" height=\"20px\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 18 32\"><path fill=\"#3b5998\" d=\"M17.1 0.2v4.7h-2.8q-1.5 0-2.1 0.6t-0.5 1.9v3.4h5.2l-0.7 5.3h-4.5v13.6h-5.5v-13.6h-4.5v-5.3h4.5v-3.9q0-3.3 1.9-5.2t5-1.8q2.6 0 4.1 0.2z\"\/><\/svg><\/span><span class=\"shariff-text\" style=\"color:#3b5998\">share<\/span>&nbsp;<\/a><\/li><li class=\"shariff-button twitter shariff-nocustomcolor\" style=\"background-color:#1e3050\"><a href=\"https:\/\/twitter.com\/share?url=https%3A%2F%2Fwww.ntg.de%2Fen%2Fprodukte%2Fteilchen-beschleuniger%2Fstrahldiagnose%2Fstrahlprofil-monitore%2Fprofilgitter%2F&text=Profile%20Grids\" title=\"Share on X (Twitter)\" aria-label=\"Share on X (Twitter)\" role=\"button\" rel=\"noreferrernoopener nofollow\" class=\"shariff-link\" style=\"; background-color:#000000; color:#000000\" target=\"_blank\"><span class=\"shariff-icon\" style=\"fill:#000000\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" height=\"1em\" viewBox=\"0 0 512 512\"><!--! Font Awesome Free 6.4.2 by @fontawesome - https:\/\/fontawesome.com License - https:\/\/fontawesome.com\/license (Commercial License) Copyright 2023 Fonticons, Inc. --><style>svg{fill:#ffffff}<\/style><path d=\"M389.2 48h70.6L305.6 224.2 487 464H345L233.7 318.6 106.5 464H35.8L200.7 275.5 26.8 48H172.4L272.9 180.9 389.2 48zM364.4 421.8h39.1L151.1 88h-42L364.4 421.8z\"\/><\/svg><\/span><span class=\"shariff-text\" style=\"color:#000000\">tweet<\/span>&nbsp;<\/a><\/li><li class=\"shariff-button linkedin shariff-nocustomcolor\" style=\"background-color:#1488bf\"><a href=\"https:\/\/www.linkedin.com\/sharing\/share-offsite\/?url=https%3A%2F%2Fwww.ntg.de%2Fen%2Fprodukte%2Fteilchen-beschleuniger%2Fstrahldiagnose%2Fstrahlprofil-monitore%2Fprofilgitter%2F\" title=\"Share on LinkedIn\" aria-label=\"Share on LinkedIn\" role=\"button\" rel=\"noreferrernoopener nofollow\" class=\"shariff-link\" style=\"; background-color:#0077b5; color:#0077b5\" target=\"_blank\"><span class=\"shariff-icon\" style=\"fill:#0077b5\"><svg width=\"32px\" height=\"20px\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 27 32\"><path fill=\"#0077b5\" d=\"M6.2 11.2v17.7h-5.9v-17.7h5.9zM6.6 5.7q0 1.3-0.9 2.2t-2.4 0.9h0q-1.5 0-2.4-0.9t-0.9-2.2 0.9-2.2 2.4-0.9 2.4 0.9 0.9 2.2zM27.4 18.7v10.1h-5.9v-9.5q0-1.9-0.7-2.9t-2.3-1.1q-1.1 0-1.9 0.6t-1.2 1.5q-0.2 0.5-0.2 1.4v9.9h-5.9q0-7.1 0-11.6t0-5.3l0-0.9h5.9v2.6h0q0.4-0.6 0.7-1t1-0.9 1.6-0.8 2-0.3q3 0 4.9 2t1.9 6z\"\/><\/svg><\/span><span class=\"shariff-text\" style=\"color:#0077b5\">share<\/span>&nbsp;<\/a><\/li><\/ul><\/div>","protected":false},"excerpt":{"rendered":"<p>&nbsp; &nbsp; Profile Grids Profile Grids are for measuring the 2d transversal intensity distribution of the beam. With our design we consider the power dissipation on the wires taking the penetration depth and the power density of the incident beam into account. We do detailed thermal simulations to stay within the feasible load limits. And [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":5817,"menu_order":10,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"on","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"class_list":["post-5811","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/pages\/5811","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/comments?post=5811"}],"version-history":[{"count":0,"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/pages\/5811\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/pages\/5817"}],"wp:attachment":[{"href":"https:\/\/www.ntg.de\/en\/wp-json\/wp\/v2\/media?parent=5811"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}